Technical Specifications Of "S" & "D" Series UPS |
|
Single in and single out
|
Three ins and single out
|
MODE |
S1K |
S2K
|
S3K
|
S6K
|
S10K |
S15K |
S20K |
D6K
|
D10K |
D15K |
D20K |
D30K |
D40K |
D50K |
D60K
|
CAPACITY (KW) |
1KVA/0.8 |
2KVA/1.6
|
3KVA/2.4
|
6KVA/4.8
|
10KVA/8
|
15KVA/12
|
20KVA/16
|
6KVA/4.8
|
10KVA/8
|
15KVA/12
|
20KVA/16
|
30KVA/24
|
40KVA/32
|
50KVA/40
|
60KVA/48
|
VOLTAGE |
Single phase with two lines + ground wire , 220V ± 25% |
Three phase with four lines + ground wire , 380V ± 25%
|
BATTERY VOLTAGE |
96V
|
192V |
192V / 384V
|
384V
|
NOISE |
≤ 52 dB ( distance 1m ) |
≤ 60 dB ( distance 1m ) |
≤ 60 dB ( distance 1m ) |
≤ 65 dB ( distance 1m ) |
SIZW ( W×D×H mm ) |
260 × 545 × 590 |
343 × 630 × 725 |
390 × 620 × 1100 |
900 × 660 × 1470 |
WEIGHT ( Kg ) (excluding the battery) |
30 |
40 |
45 |
60 |
105 |
130 |
160 |
130 |
165 |
190 |
210 |
400 |
450 |
530 |
620 |
INPUT |
FREQUENCY |
50 Hz / 60 Hz ± 10% |
POWER ACTOR |
≥ 83% |
OUTPUT |
VOLTAGE |
220V ± 0.5% |
VOLTAGE REGULATION |
Stable voltage ± 1% , dynamic voltage ± 2% , ( 0 - 100% load fluctuation 20 ms ) |
FREQUENCY STABLENESS |
50 Hz / 60 Hz ± 0.5% |
FREQUENCY TORSION RATE |
Less than 1 Hz / second |
INSTANT LOAD STATUS |
± 0.4% ( 100% instant load fluctuation ) |
HARMONIC DISTORTION |
For linear load , less than 3% ( full load ) , total rectifying harmonics is less than 5% |
OVERLOAD CAPACITANCE |
110% |
WAVE FORM |
Sine wave |
EFFICIENCY |
INPUT AC TO OUTPUT AC |
Above 95% |
TRANSFER TIME |
MAINS POWER SUPPLY FAILS OR RESTORES |
0 second |
TURNS FROM UPS TO BYPASS |
less than 4 ms |
BATTERY |
TYPE |
Lead - acid sealed , maintenance - free |
CHARGING TIME |
After it is fully charged it can be filled to 90% of the total Capacity after it is charged for 8 hours |
WARNING SOUND |
BATTERY DISCHARGE |
If the main power fails , it buzzes once every 4 seconds |
If the battery is low , it buzzes once every 1 second |
|
Single in and single out
|
Three ins and single out
|
MODE |
S1K |
S2K |
S3K |
S6K |
S10K |
S15K |
S20K |
D6K |
D10K |
D15K |
D20K |
D30K |
D40K |
D50K |
D60K |
WARNING SOUND |
BATTERY DISCHARGE |
If the battery stops discharging , it buzzes continuously |
IN FAULT STATUS |
Continuously buzzes |
INTERNAL PROTECTIN G
DEVICE LCD PANEL |
BATTERY |
Automatically shuts down the machine when the battery power is low, it has no fuse switch protection. |
OVERLOAD |
After the overload (100~110%) lasts for 3 seconds ,it automatically jumps to BYPASS.
It can automatically restore normal state. |
TEMPERATURE IS TOO HIGH |
If the internal temperature of the UPS>85°C, it will Automatically jump to BYPASS. |
OUTPUT SHORT CIRCUIT |
Limits Current, automatically shuts down the machine, without Fuse switch protection. |
UPS IS ABNORMAL |
Automatically jumps to BYPASS mode and starts direct mains power supply. |
NOISE FILTER |
10~10KHz at 40 db; 100KHz~100MHz at 70 db |
LCD DISPLAY |
Indicating input and output voltage, frequency; battery voltage and output power (%);Temperature |
BATTERY BVL |
One LED, it glows when the battery voltage is low. |
OUTSIDE ENVIRONM ENT |
TEMPERATURE |
- 10 ~ 50℃ |
RELATIVE HUMIDITY |
0%~93% (No condensation) |
OPERATION CONDITION |
Lower than 3000 meters above sea level (altitude) |
|